⚪94% charging efficiency
⚪93% feedback efficiency
⚪1S/H time accuracy
⚪255 single cycle work steps
1. Product description
Battery charging and discharging test system is a computer controlled product developed by our company. Its software design uses computer big data processing away from the program master
A way of dynamically controlling bidirectional power supply. It not only realizes the requirement of automatic charge and discharge of bidirectional power supply, but also eliminates the workload of manual recording of test data, so as to realize the battery
Fully automatic charge and discharge.
Second, functional characteristics
The system has good flexibility for the expansion of power battery test, which is convenient for users to expand and adjust the system in the future.
It can meet the requirements of various standard dynamic test procedures to meet the needs of electric vehicle battery testing.
In a single test process, the test steps can be up to 255 steps, providing users with a wide range of features.
It provides data analysis curves of charge and discharge efficiency, capacity decay rate, current-voltage characteristics, etc., and can be easily converted into EXCEL documents for saving and printing.
The test program programming is flexible and convenient. Variable and programming can be used to realize a variety of combined test programs, and various conditions of vehicle operation can be simulated.
It has functions such as emergency cut-off switch, automatic shutdown after power failure, automatic load connection and disconnection.
Software introduction
Three, work step editing module
Power IP address
Change the power port (default: 1024).
The automatic test system controls all power supplies through switches, and the communication protocol is UDP
3.1, work step editing
Battery protection parameters range
Work step process parameters
Download the edited steps to the power supply
According to the specifications of the battery, the battery voltage, current, temperature protection range is set: charge-discharge, discharge-charge
The process is larger than 10 seconds of shelving; All the edited data can be saved into a file for next use
Open the previously saved file.
3.32, work step editing
Test data
Drop down to select data
Switch between different work steps
The entire data refresh time
3.3, work step editing
Enter the box number, select the report type, and click Query.
The data in the table can be exported to EXCEL or printed directly from the printer
4. Operation interface
5. Technical parameters and specifications
|
Equipment model name |
BTS1050 |
BTS1100 |
BTS1150 |
BTS13000 |
BTS1450 |
|
|
power |
50KW |
100KW |
150KW |
300KW |
450KW |
|
|
Number of channels |
1, the upper computer software can be customized software writing and BMS docking, and two-way control |
|||||
|
System function |
1, battery cycle life test 5, battery charge/discharge efficiency test 2, battery capacity test 6, battery overcharge/overdischarge rate endurance test support 3, battery charge/discharge characteristics test CAN communication to achieve BMS data docking 4, battery charge retention ability test |
|||||
|
Ac input interface |
1, the upper computer software can be customized software writing and BMS docking, and two-way control |
|||||
|
voltage |
30-300V |
166A |
334A |
500A |
1000A |
/ |
|
50-500V |
100A |
200A |
300A |
600A |
900A |
|
|
200-750V |
66A |
133A |
200A |
400A |
600A |
|
|
300-900V |
/ |
166.7 A |
333A |
500A |
||
|
Voltage accuracy |
±0.1%of F.S±0.1%of F.D |
|||||
|
Charging efficiency |
≥94%(full load) |
|||||
|
Feedback efficiency |
≥93%(full load) |
|||||
|
Channel current range |
0.1 A |
|||||
|
Current accuracy |
±0.1%Of F.S±0.1%of F.D |
|||||
|
Radius |
Single channel 1500W~+150kW |
|||||
|
Power accuracy |
F.S±3%Of |
|||||
|
Current response time |
Current hardware response time ≤200ms |
|||||
|
Time setting range |
1000 minutes/work step |
|||||
|
precision |
1S/H |
|||||
|
Voltage and current detection sampling |
Four-wire connection |
|||||
|
Recording mode |
Voltage difference, current difference, time difference |
|||||
|
Data recording frequency |
100ms |
|||||
|
Charging mode |
Constant current, constant voltage, constant power |
|||||
|
Charging cutoff condition |
Total voltage, current, time, capacity, auxiliary voltage |
|||||
|
Discharge stop condition |
Total voltage, current, time, capacity, auxiliary voltage |
|||||
|
Protection function |
It has power failure protection function, data abnormal recovery software overvoltage protection, software undervoltage protection, software overcurrent protection, software undercurrent protection, auxiliary temperature protection, auxiliary voltage protection. At the same time, the protection voltage and current value can be set, and after the channel protection, tips and records can be displayed in the list: |
|||||
|
Number of work steps in a single cycle |
255 steps, with nested functionality |
|||||
|
Number of cycles in a single channel |
65535 |
|||||
|
software |
Binary file record, the project is not less than voltage, current, time, capacity, temperature, energy, etc., and there are corresponding curves, can be output into EXCEL file or text file; Provides constant current, constant voltage, shelving, skip, loop, loop nesting, "goto" and other functions |
|||||
|
dimension |
1680mm*800mm*2000mm(W * D * H) |
|||||
|
weight |
1500Kg |
|||||
Address: Electronic and Electrical Industrial Park, Yiyang Industrial Cluster, Luoyang City, Henan Province
Tel: 0379-60685666
Zip Code: 471000
Email: ykdq2009@126.com