Energy feedback, energy efficient
High precision (1mV.1mA)
16-bit DAC+ 24-bit ADC
ADI+TI High precision seamless constant voltage constant current switching
4, a variety of conditions (capacity, time, open circuit voltage, discharge platform, etc.) for battery sorting function. 5, automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, termination voltage and other data.
6, real-time detection of each battery voltage, charging, the first constant current charging, when the battery voltage reaches the set value, will be smoothly transferred to constant voltage charging, to meet the set time or electricity
Charging ends when the voltage terminates. When the battery voltage is lower than the set value, the discharge ends and the corresponding battery indicator lights up.

7, with power failure protection function, after the call can continue to run the original workflow.
8, the upper computer can be set up 32 working parameters, 256 cycles, each machine can be connected to I-6 testing cabinets (recommended less than 5).
Supporting software functions.
1) The graphic operation interface is used to display the voltage, current, time, capacity and other data of each battery, and the corresponding working status and abnormal conditions are displayed in various colors.
2) Any segment battery capacity indicator (up to 100 segments).
3) Data points can be recorded according to the changing conditions of voltage, current and time to form a complete charging and discharging curve data, and the curve data point time interval is 3 15 seconds.
4) A variety of conditions (capacity, time, open circuit voltage, discharge platform, etc.) for battery sorting function.
5) Automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, termination voltage and other data.
6) Operator permission setting, hierarchical operation.
7) Can display charge and discharge curves, cycle diagram.
Iv. Application scenarios
Cell factory
Battery recycling plant
6. Test monitoring data
Equipment management
Work step management
Volumetric setting
The battery node is enabled
Refresh the Settings list
6.1 Device Management
Power IP address Change Power port (Default: 1024) Automatic detection The system controls all power supplies through switches. The communication protocol is UDP
6.2 Work Step Management
Working step process parameters The edited working step is downloaded to the power supply according to the battery specifications to set the battery voltage, current, temperature protection range. All the edited data can be saved as a file for next use by opening the previously saved file 6.3 Partition Settings
6.4 Enabling a Battery Node
Setup run
Click to enable
6.5 Test Curve Diagram
7, system configuration requirements 1, the minimum configuration of the computer system :PD/300 CPU, 64MB memory, 6.4GB hard disk space, EGANGA color display, a CD-ROM, a mouse, Microsoft WindOWS 98 or above operating system, Windows 5 supported printers. 2, the computer system is configured by the user, and the number of computer systems is determined according to actual needs. 3, it is recommended that users equip each computer with UPS power supply to prevent damage to the computer or data when the power grid is cut off. 4, the device starts the instant current is large, the user for the device to configure the line power switch, need to consider the power switch action current is not lower than the starting current of the device, so as to avoid switch tripping phenomenon. 8. Technical parameters and specifications
|
Equipment model name |
BTS5V10A 256 feedback round pack lithium battery capacity test cabinet |
|
|
Equipment model name |
The equipment is mainly composed of computer and control software, control and detection power supply and mechanical horizontal pneumatic fixture. The control and detection power supply part is mainly composed of feed-type charging constant current constant voltage source, feed-type discharge constant current source, single-chip computer program and control panel, and air extraction system. Fixture part: The use of inclined tray, each tray 16 batteries, the fixture can be quickly replaced, adjust the screw adjustment, to facilitate debugging, no tool assistance. |
|
|
System input power |
15 KW |
|
|
input |
voltage |
380±10% 50Hz |
|
Electric current |
Max. 63A |
|
|
Power factor |
PF acuity 0.95 |
|
|
Current harmonic |
High quality energy feedback: discharge energy high quality feedback to the power grid, THDI≤0.05, high efficiency and energy saving, no pollution to the power grid; High efficiency, will not cause the test environment temperature rise, save the investment of other auxiliary equipment. |
|
|
Charging efficiency |
≥80% (full load) |
|
|
Feed efficiency |
≥75% (full load) |
|
|
exportation |
Test channel point |
256 pieces per set |
|
Voltage measuring range |
0~5V, resolution 1mV |
|
|
Discharge measuring range |
0.8 V ~ 5 V |
|
|
Voltage measurement accuracy |
(plus or minus 0.01% FS + 3 DGT) |
|
|
Constant voltage setting range |
DC 1.5 to 4.5V |
|
|
Constant pressure setting accuracy |
(plus or minus 0.01% FS + 3 DGT) |
|
|
Battery voltage Range of the charging voltage |
DC 0 to 5.0V |
|
|
Battery voltage Discharge voltage range |
DC 5.0 to 1.5V |
|
|
Constant current range |
0~10A, resolution 1mA |
|
|
Current setting accuracy |
(plus or minus 0.01% FS + 3 DGT) |
|
|
Accuracy of current measurement |
(plus or minus 0.01% FS + 3 DGT) |
|
|
Time frame |
0 to 30000 minutes per work step |
|
|
Data presentation |
Comprehensive data |
Set working information, station number, cycle number, test step number, termination state, open circuit voltage, average voltage, termination voltage, time, capacity, power, termination current, constant current charging capacity, constant voltage charging capacity, constant current ratio, constant voltage ratio, discharge efficiency, loss ratio, cumulative discharge capacity, capacity time voltage value of curve characteristic data points, You can choose to set conditions and so on. |
|
Classified data |
The open circuit voltage, average voltage, termination voltage, termination current, capacity, power, termination conditions and other data of the corresponding cycle or test step can be independently classified and displayed. |
|
|
Data export |
Data can be sent to EXCEL, ACCESS, WORD files, and poured into MDB database system format files. |
|
|
Curves and data |
All display mode |
The time voltage and current curves of all test steps can be displayed at the same time, and the real-time data of the curves can be displayed at the same time. |
|
Independent step display |
The required work curve can be selected according to the user's own setting, and the corresponding curve real-time data. |
|
|
Statistical statement |
Statistical data |
Enter the required statistical interval, the data can be graded statistics, qualified quantity, qualified rate, maximum value, minimum value, average value, etc., can be automatically counted out. |
|
Distribution map |
Displays graphs for each capacity interval of statistics. |
|
|
printout |
With curve data print preview, output function |
|
|
Programmable working mode and Variable control regulation |
Constant current charging (C_CC) |
Voltage cutoff, time cutoff, -△V termination value |
|
Constant Voltage charging (C_CV) |
Current cut-off, time cut-off |
|
|
REST (REST) |
Time cutoff |
|
|
Constant current discharge (D_CC) |
Voltage cut-off, time cut-off |
|
|
CYCLE (CYCLE) |
The number of terminating cycles that can be set |
|
|
Sorting method (bar code information database management system sorting, this function is only limited to users with bar code information management system requirements. Parameters related to battery internal resistance need to be configured with an internal resistance test system.) |
1, sorting by capacity 2, sorting by running time 3, platform time 4, sorting by open circuit voltage 5, constant current ratio 6, sorting by balanced voltage 7, sorting by voltage change value 8, sorting by curve fitting (characteristic voltage curve point) 9, self-discharge rate K1, K2, 10, OCVI/OCRI test time, voltage, battery internal resistance; OCV2/OCR2 test time, voltage, and battery internal resistance; OCV3/OCR3 test time, voltage, battery internal resistance; 11. The capacity and time corresponding to fixed-point platform 1; The capacity and time corresponding to the fixed platform 2; The capacity and time corresponding to the fixed platform 3; The corresponding capacity and time when the fixed point is equal to 4; The capacity and time corresponding to the fixed point platform 5; Cell capacitance voltage; Battery capacity: battery capacity duration; The single or multiple combinations of the above sorting methods can be selected according to the user |
The luminescent tube lights indicate the sorting, grouping and deriving discharge current: discharge open circuit voltage; Discharge average voltage; Discharge capacity; Discharge duration: discharge loss ratio; Discharge efficiency: discharge termination voltage; Voltage change during capacitance division: median voltage; Users can select the conditions of participation according to the actual situation to carry out sorting and pairing. |
|
Charge and discharge mode |
Constant current charging, nickel-metal hydride charging, lithium charging, constant voltage charging, constant current constant voltage charging (constant flow constant voltage smooth transition, prevent current sharp and large current to the battery, protect the battery): constant discharge, constant power discharge, constant resistance discharge: |
|
|
Charging efficiency |
≥80%(full load) |
|
|
Discharge recovery efficiency |
≥75%(full load) |
|
|
Number of cycles can be set |
1-256 times |
|
|
Cycle range |
1-9999 times |
|
|
Programmable work step |
64 work steps |
|
|
Current response speed |
Minimum step time :Is |
|
|
Sampling inspection cycle |
≤5s |
|
|
Power failure protection renewal function |
With intelligent power failure protection measures, in the battery test process, any time there is a power failure or power failure of the power supply system (CPU storage control system power failure protection renewal function with internal power support), the test system can ensure that no data loss, after re-powering, the test system has a self-recovery function, can be seamlessly connected from the last power failure. Continue the test process. |
|
|
Safety protection function |
Over voltage protection, under voltage protection, over current protection, under current protection, over capacity protection, lightning protection. Voltage sampling line break protection function: Check that the voltage sampling circuit and the current line voltage difference is greater than a certain value protection, stop charging and discharging. |
|
|
Device communication mode |
The terminal computer control equipment uses Ethernet. |
|
|
Bar code information management |
The device control system can be compatible with the BarcodeMIS battery barcode information management system through the network. |
|
|
Heat dissipation mode |
Air cooling, low noise axial fan exhaust heat dissipation. |
|
|
Working power supply |
AC380V±15%, 50Hz, maximum power consumption ≤13KW; |
|
|
Working environment |
Ambient temperature -10~40~C, relative humidity ≤90%RH. |
|
|
Structural dimension |
1520m m★900m m★1800m m(W ★ D ★ H) |
|
Address: Electronic and Electrical Industrial Park, Yiyang Industrial Cluster, Luoyang City, Henan Province
Tel: 0379-60685666
Zip Code: 471000
Email: ykdq2009@126.com