About Us
About Us
Yingkai Co., Ltd. is a high-tech enterprise that integrates solution design, product research and development, production, manufacturing, and after-sales service, focusing on the fields of new energy charging equipment and electrical equipment.
Products
Products
Yingkai Co., Ltd. is a high-tech enterprise that integrates solution design, product research and development, production, manufacturing, and after-sales service, focusing on the fields of new energy charging equipment and electrical equipment.
Solution
Solution
Yingkai Co., Ltd. is a high-tech enterprise that integrates solution design, product research and development, production, manufacturing, and after-sales service, focusing on the fields of new energy charging equipment and electrical equipment.
News
News
Yingkai Co., Ltd. is a high-tech enterprise that integrates solution design, product research and development, production, manufacturing, and after-sales service, focusing on the fields of new energy charging equipment and electrical equipment.
CN
XGN2-12Z fixed AC metal enclosed switchgear
XGN2-12Z fixed AC metal enclosed switchgear

XGN2-12Z fixed AC metal-enclosed switchgear (switchgear for short) is suitable for rated voltage 3.6~12KV, 50Hz, rated current 630A~4000A three-phase AC single bus, double bus, single bus with bypass system, as receiving and distribution Use of electrical energy. It can meet the use requirements of various types of power plants, substations (stations) and industrial and mining enterprises. This product complies with the national standards GB3906 "3-35KV AC Metal-Enclosed Switchgear", IEC60298 "AC Metal-Enclosed Switchgear and Control Equipment", DL/402, and DLT404 standards, and meets the five anti-locking requirements.

Service Hotline: 0379-60685666
Product Details
Conditions of use

a. Ambient air temperature: -15℃~+40℃;

b. Altitude: 1000M and below;

c. Humidity conditions: the daily average value is not greater than 95%, the daily average water vapor pressure is not more than 2.2kPa, the monthly average value is not more than 90%, and the monthly average water vapor pressure is not more than 1.8kPa;

d. Earthquake intensity: no more than 8 degrees;

e. Places without corrosive or flammable gases or other obvious pollution.

Note: If you have special requirements, you can negotiate with our company to resolve them.

Model and meaning

Technical parameters

project unit data
Rated voltage KV 3.6 7.2 12
Rated current A 630~4000
Rated short circuit breaking current THE 16.20.31.5.40
Rated short circuit making current (peak value) THE 40.50.80.100
Rated withstand current (peak) THE 40.50.80.100
Rated short-time withstand current THE 16.20.31.5.40
Rated short circuit duration S 4
Protection level IP2X
Main wiring form Single bus segmentation and single bus with bypass
Operational structure Electromagnetic and spring energy storage
Overall dimensions (width*depth*height) MM 1100*1200*2650(general type)
weight KG 1000
Structural
Features Rooms are separated by steel plates.
1. The circuit breaker room is in the front and lower part of the cabinet. The rotation of the circuit breaker is connected by the pull rod and the operating mechanism. The upper terminals of the circuit breaker are connected to the upper isolating switch. The lower terminals of the circuit breaker are connected to the current transformer. The current transformer is connected to the lower The terminal block of the isolating switch is connected, and the circuit breaker chamber is also equipped with a pressure relief channel. If an internal arc occurs, the gas can release the pressure through the pressure relief channel.
2. The busbar room is in the upper rear part of the cabinet. In order to reduce the height of the cabinet, the busbars are arranged in a Z-shape and supported by porcelain insulators with a bending strength of 7350N. The busbars are connected to the upper isolating switch terminals. Between the busbar rooms of two adjacent cabinets Can be isolated.
3. The cable room is behind the lower part of the cabinet. The supporting insulator in the cable room can be equipped with a voltage monitoring device, and the cables are fixed on the bracket. When the main wiring is a contact scheme, this room is the contact cable room. The relay room is in front of the upper part of the cabinet, and various relays can be installed on the indoor mounting plate. There is a terminal block bracket in the room, and secondary components such as indicating instruments and signal components can be installed on the door. A small secondary busbar can also be arranged on the top.
4. The operating mechanism of the circuit breaker is installed on the left side of the front. Above it is the operating and interlocking mechanism of the isolating switch. The switch cabinet is double-sided for maintenance. Check the secondary components, maintenance operating mechanism, mechanical interlocking and transmission in the relay room from the front. Partially, inspect the circuit breaker. Main busbars and cable terminals are serviced at the rear, and lights are installed in the circuit breaker room. There is a grounding copper busbar parallel to the width of the cabinet under the front door, with a cross-section of 5*50.
5. Mechanical interlocking: To prevent the isolating switch from opening and closing under load, to prevent the circuit breaker from being opened and closed by mistake, and from entering the live interval by mistake. To prevent the grounding switch from being powered on and the grounding knife from closing, the switch cabinet adopts corresponding mechanical interlocking.
Ordering instructions
When ordering, the following information must be provided:
a. Main wiring plan number and busbar system diagram, arrangement diagram;
b. Secondary circuit wiring schematic diagram, terminal arrangement diagram, if there is no arrangement diagram for the terminals, follow the manufacturer's regulations;
c. Electrical appliances in the switchgear The model, specification and quantity of the components;
d. The material specifications of the main bus and branch buses, otherwise they shall be supplied according to the manufacturer's regulations;
e. When the switch cabinet is used in special environmental conditions, it should be mentioned when ordering
f. When accessories and spare parts are needed, it should be mentioned its type and quantity.
Switch cabinet outline drawing

Related Products
Product Inquiry

Product Name: XGN2-12Z fixed AC metal enclosed switchgear

Contact Us

Address: Electronic and Electrical Industrial Park, Yiyang Industrial Cluster, Luoyang City, Henan Province

Tel: 0379-60685666

Zip Code: 471000

Email: ykdq2009@126.com

Copyright 2024 © Henan Yingkai Electric Co., Ltd. Technical Support: ShangXian SITEXML

Home

Tel

Top