XL-21 is installed against the wall and is an indoor closed distribution box. The box structure is made of thin steel plates that are bent and welded or assembled with bolts. The upper and lower ventilation windows and incoming and outgoing cables are introduced from the bottom. If users have special requirements, they can also drill knock-out holes for line entry or install a busbar room on the top cover of the box. Its shell protection grade is not less than IP30. The technology complies with the standard requirements of GB7251 and is suitable for indoor normal use conditions. The rated insulation voltage is 660V, the rated working voltage is AC 380V, the rated frequency is 50Hz, and the rated current is up to 630A in the power distribution system, and it is used as power, lighting and power distribution in industrial and mining enterprises, residences, institutions, public buildings and other places.
Installation, use and maintenance
1. The power distribution box can be packed and transported only after passing the inspection. When the product arrives at the destination , you should first check whether the packaging is complete. If the power distribution box is not to be installed , the product should be stored in a dry and clean place.
2. The power distribution box can be installed according to the installation diagram. The basic channel steel and screws are prepared by the user. If the cable is to be outlet, the user needs to bury the basic channel steel and foot bolts and the foreign supplier needs to open a cable trench.
3. After the power distribution box is installed or repaired, the following .
a. Check whether the internal electrical equipment and circuits comply with the original design drawing.
b. Check and operate the switch several times to see if it is flexible and normal;
c. Check and test whether all meters and relays operate accurately.
Conditions of use
a. The altitude should not exceed 2000 meters;
b. Ambient temperature: the ambient air temperature should not be higher than +40°C;
c. There should be no excess dust, acid, salt, corrosive and explosive gases in the air. The relative temperature does not exceed 50% at the highest temperature +40°C. At the lowest temperature, a higher temperature change is allowed and general condensation may occasionally occur.
Structural features
1. The fixed structural appearance and installation dimensions of the power distribution box are shown in the table;
2. The combination form of the power distribution box and the branch plan are unitized;
3. The combined appearance dimensions and installation dimensions of the power distribution box are consistent with The fixed structure is the same.
Classification | Overall dimensions | illustrate | ||
A | B | C | ||
I | 1700 | 600 | 370 | Single power feed and lighting |
II | 1700 | 600 | 470 | Single unit receiving power |
III | 1700 | 700 | 370 | Single unit receiving power and lighting |
IV | 1800 | 600 | 470 | Joint spelling, power receiving, power feeding, lighting |
V | 1800 | 700 | 470 | Joint spelling, power receiving, power feeding, lighting |
VI | 1700 | 800 | 370 | Single power feed and lighting |
VII | 1800 | 800 | 470 | Joint spelling, power receiving, power feeding, lighting |